Product Details:
Payment & Shipping Terms:
|
Type: | Plug Lockout | Material: | Plastic ABS |
---|---|---|---|
Color: | Red | Padlocks Equipped: | 4 Pcs Padlocks |
Shackle Diameter: | Less Than 7 Mm | Usage: | Oil, Chemical, Led Lighting, Industrial Manufacturing |
Label: | PVC Tag Is Availble | Language: | English Or OEM |
New Technology Hot Selling Electrical or Pneumatic Plug Lockout
Product Details:
ZC-D31 Electrical plug lockout
1. Made from industrial plastic ABS.
2. Double open type quadrangle design, can lock out all kinds of electrical plugs and air hole male connector.
3. Can apply maximum 54 pcs padlocks whose shackle diameter <=7mm.
Model No | Description |
ZC-D31 | 59.7cm(height)*9.5cm(thickness)*17cm(width), hole diameter: 9.5mm, 10.4mm,11.4mm,12mm,18.2mm. |
Product Features:
1. plug lockout is used to avoid electrical accidents.
2. plug lockout suitable for all types of plugs.
3. Completely encloses electrical plugs to prevent accidental re-connection.
4. OEM is accepted.
Application:
Completely enclosed electrical plugs to prevent accidental re-connection.
Related Breaker lockouts , MCB Lockout :
ZC-D01 (Pin Out Standard ) ,
ZC-D02(Pin in Standard),
ZC-D03(Pin Out Wide),
ZC-D04(Tie Bar Lockout)
ZC-D05 MCB locout
ZC-D06 Moulded Case Circuit Breaker Lockout (51mm*25mm*23mm),
ZC-D07(125*63*40MM)
ZC-D08 & D09 MCB Lockout device
ZC-D10 Universal Miniature Breaker Lockout (Multi-functional MCB Lockout)
Clamp-on Breaker Lockout
ZC-D14 (120-277V),
ZC-D15 (480-600V);
ZC-D16 (480-600V)
ZC-D14 MCB Lockout 51*25*23mm
ZC- D15 MCB Lockout 125*63*40mm
ZC-D21 Snap-On Breaker Lockout 55*9*21mm , For 120V breaker
Electrical/Pneumatic Plug Lockout
ZC-D31 110v,220v & 550V Plugs
ZC-D41 For 110v plug Electrical Plug Lockout
ZC-D42 for 220/550v plugs Electrical Plug Lockout
D51/52/53/54 22-38mm Emergency Stop Lockout
ZC-D61 Single lockable socket cover for switch
ZC-D62 double lockable socket cover for switch
About sample:
We are willing to supply sample to customer test the products quality
Sample fee and shipping cost, buyer afford,
About Quotation Validity Date:
Our company quotation validity time is 30 days from the quotation day.
About Payment Term:
Our company accept T/T, L/C, D/P and another payment term
About Production Time:
Different products and quantity have different production time
Why Use Lockout/Tag out
Due to the hight rate of industrial accidents caused by unexpected organization, start up od machines or equipment, uncontrolled release of energy, reducing the industrial accidents becomes one of today’s most serious issues. LOCKOUT/TAGOUT is a planned safety procedure that disables the energy supply of industrial machinery and equipment whilst servicing, maintenance work or repairs are in progress. Many of industrial accidents can be prevented by proper LOCKOUT/TAGOUT procedures.
Making the right kind of LOCKOUT & TAGOUT equipment available to the employee is the responsibility of the plant’s management.
Where use LOCKOUT/TAGOUT?
1.Perform daily maintenance on the equipment,adjustment,cleaning,inspection and debugging etc.
2.Operation under high pressure
3.The operation that needs to temporarily turn off the security system.
4.Widely used in petrochemical,chemical,nuclear power,military automobile ship building industries,suitable for oil pipelines,cable interlayer,platform channel,pup house,Tunnel Project,Mountain-climbing,Hiking,Patrolling,Overhauling and Emergency in electrical power company,Mine,Military,Police,Firefighting,Dockyard and other hazardous locations.
LOCKOUT/TAGOUT Requirements
1.If more than one individual is required to work on a particular piece of equipment,each shall place his own personal LOCKOUT/TAGOUT device on the energy isolating devices.
2.Never authorize to other employees to remove your LOGO devices.
3.During work shift,never remove your LOCKOUT/TAGOUT devices before another to confirm the LOCKOUT/TAGOUT devices are safety and then begin operations.
4.Each LOCKOUT/TAGOUT device with the name of the employee for operations.
Each employee can't continue operations depend on others' LOCKOUT/TAGOUT devices.
5.Proper application and utilization of LOCKOUT/TAGOUT devices.
6.A periodic inspection of the energy control procedures shall be conducted at least annuanlly to ensure that the procedure and the requirments of this standard are being followed.
7.If there is a poss ability of re-accumulation no longer exists.
8.Outside person,such as contractors,must be aware of the LOTO procudures of the Company.This is best accomplished with outside person during the initial meeting where a copy of the Company's LOTO program can be presented and discussed along with oher safety program requirments.
Applications
1.Learn well how to use the equipment.
The quthorized employee shall know well the power supply equipment's position.performance and how to control the power source LOCKOUT/TAGOUT procedure also will present which power source,switch need lockout.And please comply with the LOCKOUT/TAOUT procedure on devices
2.Notify personnel.
Notify all relative operators before setting LOCKOUT/TAGOUT devices to avoid error operating accidents.
3.Shutdown equipment
Power switch off,or in a state of grounding,and apply TAGOUT to warn others.
4.De-Energize and lock power source.
Use LOCKOUT/TAGOUT for hazardous power source,e.g. use circuit breaker lockout to lock the circuit breaker or valve lockout to lock valve.
5.Release stored energy.
Must release stored energy before maintaining.The release stored energy is hidden may cause personal injury in the case of unknown the equipment starts up suddenly.
6.Verify zero energy state
In any case,in the event of the change of LOCKOUT/TAGOUT,it must be assured that the device is at zero energy state before work resumes.This step must be operated by authorized person,the verification results of other employee are regarded as invalid.
7.Restor the LOCKOUT/TAGOUT devices
Please restoring the LOCKOUT/TAGOUT devices immediately after testing,If it needs to remove the LOCKOUT/TAGOUT devices for equipment testing.
8.Remove LOCKOUT/TAGOUT devices
Work completed,before remove LOCKOUT/TAGOUT devices,please ensure nobody around the machines or equipment and notify relevant persons this equipment will re-startup.Only authorized employees can remove LOCKOUT/TAGOUT devices.
Our company
Why choose Zhou Chuang ?
About us
Some of our strengths that make us your most reliable business partner are:
1) Extensive industry knowledge / experience
2) Wide range of products for diverse applications in various industry segments
3) Our comprehensive quality policy
4) Reliable, well-organized and efficient distribution network
5) Competitive prices
6) Our stable business model, robust finance,honest value system and customer-centric approach.
Warranty and ater-sales service
1) Warranty: 1 years, for defective one, we will replace a total new cap lamp during warranty time
2) After sales service: will deal with your complaint at first time, give you solution within 5 working days
3) Free samples: free samples will be provided when our new models come out
4) Market support: we can support you to do advertisment in local magazine and provide samples with
big discount for exhibition
Packing &Delivery
10Pcs/Box 20Pcs/Carton 20kg/Carton
We can customized the package for our customer,any requirements welcome to tell us.
FAQ
1. If you couldn’t find the exact product you want, never mind, just contact us and tell your requirements, we will arrange the moulds and manufacture for you.
2. No minimum order quantity required
3. Many products are available from stock with the next several days.
4. If required, goods can be collected from our factory directly to your customers.
5. We also support OEM manufacturing, with any given order quantity.
Contact us
Shen Zhen Zhou Chuang Technology Co., Ltd
Add: No.2 Bldg,Da Pu Industrial,Long Dong Community,Long Gang District, Shen Zhen City, China.
Tel: +86-755-84829400 Fax:+86-755-84820206
Cell: +86 13603090255
Skype: glsafety08@outlook.com E-mail: sales8@zhouchuangsz.com